GEA PHE Systems  /Italy
1
Receipt and inspection of the plates
3
Chemical cleaning depending on the type of soiling
5
Removing the residues from the dye penetration test
7
Alignment and repair of gasket groove if required
9
Tensioning the plate pack with subsequent accelerated hardening of the adhesive in the furnace
2
Thorough removal of the old gasket
4
Checking the plates for hairline cracks and contact corrosion
6
Thorough cleaning and check of gasket groove
8
Fitting of the gasket
10
This is followed by an inspection of every plate and careful packaging for transportation